562A011-3-00-0

TE Connectivity
Special Order: 562A011-3-00-0 Molded Part Shape: Y Shape Number of Branches & Legs: 5 Material Code: 3 Material Systems Code: 10 Adhesive Requirement: Adhesive Purchased Separately Y Shape 5 3 10 | Heat Shrinkable Cable Breakout And Cable Transition | Part Number: 562A011-3-00-0 | Internal Number: 823040-000 | Alias Number: 6-1196420-5 | TE Connectivity
$19.26 - $55.66Distributors
Currency:
Distributor | SKU | Stock | MOQ | 1 | 10 | 50 | 100 | 1000 | 10000 | Purchase | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AVNET Express | 562A011-3-00-0 | 1 | $51.69 | $47.37 | $47.37 | $47.37 | $47.37 | Buy | |||
![]() |
Mouser Electronics | 650-562A011-3-00-0 | 0 | 100 | $19.26 | $17.66 | $17.66 | Buy | ||||
![]() |
TE Connectivity | 562A011-3-00-0 | $55.52 | $55.52 | $55.52 | $55.52 | $55.52 | $55.52 | Buy | |||
![]() |
Heiland | RYC562A011-3-00-0 | Buy |
Technical Specifications
Adhesive Code | S1017 |
Adhesive Code | S1048 |
Adhesive Options | S1048 Separate Adhesive |
Adhesive Options | S1017 Separate Adhesive |
Adhesive Pre-Coat | No |
Adhesive Type | Adhesive Purchased Separately |
Breakout Angle | 45 |
Color | Black |
Fluid/Chemical Resistance | Occasional exposure to fluids |
Government Qualified | No |
Inside Diameter Range (Body) | .27 – .52 |
Inside Diameter Range (Body) | 6.9 – 13.2 |
Inside Diameter Range (Leg 1) | 3.5 – 6.6 |
Inside Diameter Range (Leg 1) | .14 – .26 |
Inside Diameter Range (Leg 2) | .14 – .26 |
Inside Diameter Range (Leg 2) | 3.5 – 6.6 |
Inside Diameter Range (Leg 3) | .14 – .26 |
Inside Diameter Range (Leg 3) | 3.5 – 6.6 |
Inside Diameter Range (Leg 4) | 3.5 – 6.6 |
Inside Diameter Range (Leg 4) | .14 – .26 |
Material | Semi-Rigid Modified Polyolefin |
Material Code | 3 |
Material Systems Code | 10 |
Molded Part Shape | One to Four Cables |
Molded Part Type | Transition |
Number of Branches/Legs | 4 |
Operating Temperature Range | -67 – 275 |
Operating Temperature Range | -55 – 135 |
Pliancy | Semi-Rigid |
Power Cable Accessory | No |
Product Type | Molded Part |
Size Code | 11 |
Special Requirements | Flame Retarded |
Transition Type | 1 to 4 Cables |
Wire/Cable Main Branch OD | .18 |
Wire/Cable Main Branch OD | 4 |
Wire/Cable Main Branch OD | 5 |
Wire/Cable Main Branch OD | 4.5 |
Wire/Cable Main Branch OD | .16 |
Wire/Cable Main Branch OD | .2 |
Wire/Cable OD | 10 |
Wire/Cable OD | 9 |
Wire/Cable OD | .35 |
Wire/Cable OD | 8 |
Wire/Cable OD | .31 |
Wire/Cable OD | .39 |
Wire/Cable Sm Branch OD | .2 |
Wire/Cable Sm Branch OD | 5 |
Wire/Cable Sm Branch OD | .18 |
Wire/Cable Sm Branch OD | 4.5 |
Wire/Cable Sm Branch OD | 4 |
Wire/Cable Sm Branch OD | .16 |