LKSR 15-NP
LEM
Current Sensor 15A 1 Channel Hall Effect, Closed Loop Bidirectional Module
15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to + 105°C, Reference access, Primary integrated conductors , 100 % fully compatible with CKSR 15-NP
Features:
- Closed loop multi-range current transducer
- Voltage output
- Unipolar supply voltage
- Compact design for PCB mounting
Applications:
- AC variable speed and servo motor drives
- Static converters for DC motor drives
- Battery supplied applications
- Uninterruptible Power Supplies (UPS)
- Switched Mode Power Supplies (SMPS)
- Power supplies for welding applications
- Solar inverters.
Distributor | SKU | Stock | MOQ | 1 | 10 | 50 | 100 | 1,000 | 10,000 |
---|---|---|---|---|---|---|---|---|---|
element14 APAC | LKSR 15-NP | 35 | 1 | * $16.35 | * $14.32 | * $13.20 | * $12.81 | * $12.81 | * $12.81 |
Farnell | LKSR 15-NP | 35 | 1 | * $15.75 | * $15.44 | * $14.81 | * $14.50 | * $14.50 | * $14.50 |
Newark | LKSR 15-NP | 35 | 1 | $21.19 | $20.23 | $17.15 | $14.96 | $14.96 | $14.96 |
LA 55-P/SP1
LEM
CURRENT TRANSDUCER 50A PCB; Sensor Output:Closed Loop; Supply Voltage DC Min:-; Supply Voltage DC Max:15V; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:-; Accuracy %:0.9%; Product Range:LA 55-P Series; SVHC:No SVHC (12-Jan-2017)
Distributor | SKU | Stock | MOQ | 1 | 10 | 50 | 100 | 1,000 | 10,000 |
---|---|---|---|---|---|---|---|---|---|
element14 APAC | LA 55-P/SP1 | 462 | 1 | * $34.70 | * $33.96 | * $29.64 | * $26.04 | * $26.04 | * $26.04 |
Farnell | LA 55-P/SP1 | 497 | 1 | * $32.74 | * $31.43 | * $30.13 | * $30.13 | * $30.13 | * $30.13 |
Newark | LA 55-P/SP1 | 407 | 1 | $46.07 | $41.99 | $39.12 | $37.02 | $37.02 | $37.02 |
TQL100A
Multicomp
CURRENT TRANSDUCER CLOSEDLOOP 100A; Sensor Output:Closed Loop; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-150A to 150A; Current Measuring Range AC:-; Response Time:2µs; Accuracy %:0.3%; Product Range:-; Accuracy:±0.3% of Ipn; Current Consumption:15mA; Current Range AC:100A; Current Range DC:±100A; Frequency Max:150kHz; Supply Voltage Range DC:± 12V to ± 15V
TH10A
Multicomp
CURRENT TRANSDUCER OPEN LOOP 10A; Sensor Output:Voltage; Supply Voltage DC Min:14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:5µs; Accuracy %:-; Product Range:-; Current Consumption:12mA; Current Range AC:10A; Current Range DC:±10A; Frequency Max:50kHz; Supply Voltage Range DC:± 14.25V to ± 15.75V
TH30A
Multicomp
CURRENT TRANSDUCER OPEN LOOP 30A; Sensor Output:Voltage; Supply Voltage DC Min:14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:5µs; Accuracy %:-; Product Range:-; Current Consumption:12mA; Current Range AC:30A; Current Range DC:±30A; Frequency Max:50kHz; Supply Voltage Range DC:± 14.25V to ± 15.75V
TH3A
Multicomp
CURRENT TRANSDUCER OPEN LOOP 3A; Sensor Output:Voltage; Supply Voltage DC Min:14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:5µs; Accuracy %:-; Product Range:-; Current Consumption:12mA; Current Range AC:3A; Current Range DC:±3 A; Frequency Max:50kHz; Supply Voltage Range DC:± 14.25V to ± 15.75V
TH5A
Multicomp
CURRENT TRANSDUCER OPEN LOOP 5A; Sensor Output:Voltage; Supply Voltage DC Min:14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Time:5µs; Accuracy %:-; Product Range:-; Current Consumption:12mA; Current Range AC:5A; Current Range DC:±5A; Frequency Max:50kHz; Supply Voltage Range DC:± 14.25V to ± 15.75V
TMA400A
Multicomp
CURRENT TRANSDUCER OPEN LOOP 400A; Sensor Output:Voltage; Supply Voltage DC Min:14.25V; Supply Voltage DC Max:15.75V; Current Measuring Range DC:-900A to 900A; Current Measuring Range AC:-900A to 900A; Response Time:10µs; Accuracy %:-; Product Range:-; Current Consumption:15mA; Current Range AC:400A; Current Range DC:±400A; Frequency Max:50kHz; Supply Voltage Range DC:± 14.25V to ± 15.75V