TE Connectivity
1-770988-0
|
TE Connectivity
770988-3
|
TE Connectivity
1-794772-0
|
TE Connectivity
794772-8
|
TE Connectivity
3-794636-4
|
TE Connectivity
1-794607-2
|
TE Connectivity
207541-7
|
TE Connectivity
1-794407-0
|
TE Connectivity
927231-5
|
TE Connectivity
1-1775441-0
|
| Price |
|
|
|
|
|
|
|
|
|
|
|
| RoHS |
|
|
|
|
|
|
|
|
|
|
|
| Lead Status |
|
|
|
|
|
|
|
|
|
|
|
| Contact Current Rating (Max) |
|
11.2 |
11.2 |
|
|
5 |
5 |
|
11.2 |
|
|
| Contact Angle |
|
Straight |
Straight |
|
|
|
Straight |
|
Straight |
|
|
| Accepts Wire Insulation Diameter Range |
|
.059 – .094 |
.059 – .094 |
|
|
|
.035 – .05 |
|
.079 – .126 |
|
|
| Mating Pin Diameter |
|
1 |
1 |
|
|
|
|
|
1 |
|
|
| Agency/Standard |
|
UL |
UL |
|
|
CSA |
|
|
UL |
CSA |
|
| Glow Wire Rating |
|
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
|
|
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
|
Standard Part - Not Glow Wire |
GWT 750°C (Without Flame) |
|
| CSA Rating |
|
Certified |
Certified |
|
|
Certified |
|
|
Certified |
Certified |
|
| Termination Type |
|
Crimp |
Crimp |
|
|
|
Crimp |
|
Crimp |
|
|
| Underplate Material Thickness |
|
1.27 |
1.27 |
|
|
|
1.27 |
|
1.27 |
|
|
| Contact Termination Area Plating Thickness |
|
2.54 |
2.54 |
|
|
100 |
2.54 |
|
2.54 – 6.35 |
|
|
| Contact Mating Area Plating Thickness |
|
.76 |
.76 |
|
|
2.54 – 7.62 |
.76 |
|
.76 |
|
|
| Contact Type |
|
Socket |
Socket |
|
|
Pin |
Socket |
|
Socket |
Pin |
|
| Crimp Area Plating Thickness |
|
2.54 |
2.54 |
|
|
|
2.54 |
|
100 – 250 |
|
|
| Wire/Cable Type |
|
Discrete Wire |
Discrete Wire |
|
|
|
Discrete Wire |
|
Discrete Wire |
|
|
| Connector & Contact Terminates To |
|
Wire & Cable |
Wire & Cable |
|
|
Printed Circuit Board |
Wire & Cable |
|
Wire & Cable |
Wire & Cable |
|
| Wire/Cable Size |
|
22 – 18 |
22 – 18 |
|
|
|
30 – 26 |
|
20 – 16 |
|
|
| Contact Mating Area Plating Material |
|
Gold |
Gold |
|
|
Tin |
Gold |
|
Gold |
|
|
| Wire Contact Termination Area Plating Material |
|
Tin |
Tin-Lead |
|
|
|
Tin |
|
Tin |
|
|
| VDE Tested |
|
Yes |
Yes |
|
|
Yes |
|
|
Yes |
Yes |
|
| Wire Insulation Support |
|
Without |
Without |
|
|
|
Without |
|
Without |
|
|
| Packaging Method |
|
Bag |
Bag |
Package |
Package |
Box & Tray |
Reel |
|
Reel |
Box & Carton |
|
| Product Type |
|
Contact |
Contact |
Accessory |
Accessory |
Header |
Contact |
|
Contact |
Housing |
|
| UL Rating |
|
Recognized |
Recognized |
|
|
Recognized |
|
|
Recognized |
Recognized |
|
| Contact Retention in Housing |
|
With |
With |
|
|
|
With |
|
With |
|
|
| Circuit Application |
|
Power |
Power |
|
|
Power |
Power |
|
Power |
Power & Signal |
|
| Contact Termination Area Plating Material |
|
Tin |
Tin-Lead |
|
|
Tin |
Tin |
|
Tin |
|
|
| Operating Voltage |
|
600 |
600 |
|
|
250 |
250 |
|
600 |
600 |
|
| CSA File Number |
|
LR 7189 |
LR 7189 |
|
|
LR7189 |
|
|
LR 7189 |
LR7189 |
|
| For Multiple Crimp |
|
No |
No |
|
|
|
No |
|
No |
|
|
| Crimp Area Plating Finish |
|
Bright |
Bright |
|
|
|
Bright |
|
Matte |
|
|
| Contact Base Material |
|
Brass |
Brass |
|
|
|
Phosphor Bronze |
|
Brass |
|
|
| Contact Underplating Material |
|
Nickel |
Nickel |
|
|
|
Nickel |
|
Nickel |
|
|
| For Use With |
|
Plug Housing |
Plug Housing |
Mini Universal MATE-N-LOK Sealed Connector |
Mini Universal MATE-N-LOK Sealed Connector |
|
|
|
Plug Housing |
Universal MATE-N-LOK Plug or Socket Housing |
|
| Operating Temperature Range |
|
-67 – 221 |
-67 – 221 |
-40 – 194 |
-40 – 194 |
-40 – 221 |
-40 – 221 |
|
-67 – 221 |
-55 – 125 |
|
| UL File Number |
|
E28476 |
E28476 |
|
|
|
|
|
E28476 |
|
|
| Connector Mounting Type |
|
Cable Mount |
Cable Mount |
|
|
Board Mount |
Cable Mount |
|
Cable Mount |
Panel |
|
| Wire Type |
|
Stranded |
Stranded |
|
|
|
Stranded |
|
Stranded |
|
|
| Packaging Quantity |
|
1000 |
1000 |
1000 |
1000 |
175 |
15000 |
|
4500 |
1000 |
|
| Connector System |
|
Wire-to-Wire |
Wire-to-Wire |
|
|
Wire-to-Board |
Wire-to-Wire |
|
Wire-to-Wire |
Wire-to-Wire |
|
| Material |
|
|
|
Urethane Foam |
Urethane Foam |
|
|
|
|
|
|
| Seal Material |
|
|
|
Urethane Foam |
Urethane Foam |
|
|
|
|
|
|
| Accessory Type |
|
|
|
Interface Seal |
Interface Seal |
|
|
|
|
|
|
| Contact Termination Area Plating Finish |
|
|
|
|
|
Matte |
|
|
|
|
|
| Termination Method to Printed Circuit Board |
|
|
|
|
|
Surface Mount |
|
|
|
|
|
| Number of Positions |
|
|
|
|
|
4 |
|
|
|
9 |
|
| PCB Thickness (Recommended) |
|
|
|
|
|
1.57 |
|
|
|
|
|
| Housing Material |
|
|
|
|
|
High Temperature Nylon |
|
|
|
PA 6 GF |
|
| Housing Color |
|
|
|
|
|
Black |
|
|
|
Natural |
|
| Agency/Standard Number |
|
|
|
|
|
E28476 |
|
|
|
E28476 |
|
| PCB Mount Retention Type |
|
|
|
|
|
Hold-Down Post |
|
|
|
|
|
| Number of Rows |
|
|
|
|
|
2 |
|
|
|
3 |
|
| Contact Retention |
|
|
|
|
|
Without |
|
|
|
Without |
|
| Multiple Contact Types |
|
|
|
|
|
Without |
|
|
|
Without |
|
| UL Flammability Rating |
|
|
|
|
|
UL 94V-0 |
|
|
|
UL 94V-2 |
|
| Strain Relief |
|
|
|
|
|
Without |
|
|
|
|
|
| PCB Mount Alignment |
|
|
|
|
|
Without |
|
|
|
|
|
| PCB Mount Orientation |
|
|
|
|
|
Vertical |
|
|
|
|
|
| Row-to-Row Spacing |
|
|
|
|
|
3 |
|
|
|
6.35 |
|
| Number of Power Positions |
|
|
|
|
|
4 |
|
|
|
|
|
| Mating Retention Type |
|
|
|
|
|
Locking Tab |
|
|
|
|
|
| PCB Mount Retention |
|
|
|
|
|
With |
|
|
|
|
|
| Termination Post & Tail Length |
|
|
|
|
|
3.18 |
|
|
|
|
|
| Termination Post &Tail Length |
|
|
|
|
|
.125 |
|
|
|
|
|
| Housing Type |
|
|
|
|
|
Plug |
|
|
|
Receptacle |
|
| Mating Retention |
|
|
|
|
|
With |
|
|
|
|
|
| Mating Alignment |
|
|
|
|
|
With |
|
|
|
|
|
| Centerline (Pitch) |
|
|
|
|
|
3 |
|
|
|
6.35 |
|
| Panel Mount Feature |
|
|
|
|
|
Without |
|
|
|
With |
|
| Mating Alignment Type |
|
|
|
|
|
Polarization |
|
|
|
|
|
| Sealable |
|
|
|
|
|
No |
|
|
|
No |
|
| Contact Retention Type within Housing |
|
|
|
|
|
|
Locking Lance |
|
|
|
|
| Glow Wire Material Rating |
|
|
|
|
|
|
|
|
|
Material with GWF1 850°C |
|
| Assembly Integration Feature |
|
|
|
|
|
|
|
|
|
Without |
|
| Contact Layout |
|
|
|
|
|
|
|
|
|
Matrix |
|
| Panel Thickness |
|
|
|
|
|
|
|
|
|
.76 – 2.29 |
|
| Termination Method to Wire & Cable |
|
|
|
|
|
|
|
|
|
Crimp |
|
| Panel Mount Feature Type |
|
|
|
|
|
|
|
|
|
Patch & Tabs |
|