TE Connectivity
2-1472973-2
|
TE Connectivity
2-1423161-8
|
TE Connectivity
3-1423179-3
|
TE Connectivity
5-1462039-9
|
TE Connectivity
1462043-2
|
TE Connectivity
3-1462051-1
|
TE Connectivity
1-1462039-7
|
TE Connectivity
1462052-1
|
TE Connectivity
1462042-2
|
TE Connectivity
3-1462039-8
|
| Price |
|
|
|
|
|
|
|
|
|
|
|
| RoHS |
|
|
|
|
|
|
|
|
|
|
|
| Lead Status |
|
|
|
|
|
|
|
|
|
|
|
| Option |
|
Double Quick Connect Terminals |
|
|
|
|
|
|
|
|
|
| Repeatability (Max) |
|
±5% |
|
|
|
|
|
|
|
|
|
| Contact Current Rating |
|
10A@240VAC |
|
|
2 |
2 |
2 |
5 |
2 |
4 |
5 |
| Dimensions (L x W x H) (Approximate) |
|
114.8 x 82.55 x 78.48 |
|
|
.393 x .236 x .222 |
.393 x .236 x .222 |
14.9 x 7.5 x 10.5 |
.393 x .236 x .222 |
14.9 x 7.5 x 10.5 |
.393 x .236 x .222 |
.393 x .236 x .222 |
| Type of Control |
|
Knob |
|
|
|
|
|
|
|
|
|
| Mounting Type |
|
Mounting Bracket |
|
|
Printed Circuit Board |
Printed Circuit Board |
Printed Circuit Board |
Printed Circuit Board |
Printed Circuit Board |
Printed Circuit Board |
Printed Circuit Board |
| Contact Arrangement |
|
2 Form C, DPDT, 2 C/O |
|
|
2 Form C (2 CO) |
2 Form A (NO) |
1 Form C (CO) |
2 Form C (2 CO) |
1 Form C (CO) |
1 Form C (CO) |
2 Form C (2 CO) |
| Mode of Operation |
|
On-Delay |
|
|
|
|
|
|
|
|
|
| Relay Type |
|
Time Delay |
|
|
IM Relay |
IM Relay |
HF3 S Relay |
IM Relay |
HF6 Relay |
IM Relay |
IM Relay |
| Product Type |
|
Relay |
|
|
Relay |
Relay |
Relay |
Relay |
Relay |
Relay |
Relay |
| Operating Temperature Range |
|
-30 – 75 |
|
|
-40 – 85 |
-40 – 85 |
|
-40 – 85 |
|
-40 – 85 |
-40 – 85 |
| Actuating System |
|
DC |
|
|
DC |
DC |
DC |
DC |
DC |
DC |
DC |
| Input Voltage |
|
60 |
|
|
|
|
|
|
|
|
|
| Multiple Timing Ranges |
|
Without |
|
|
|
|
|
|
|
|
|
| Delay Time |
|
1.5 – 15 seconds |
|
|
|
|
|
|
|
|
|
| Termination Type |
|
Screw Terminal |
|
|
Through Hole |
Surface Mount |
|
Surface Mount |
|
Surface Mount |
Through Hole |
| Product Category |
|
Electromechanical Relays |
|
|
|
|
|
|
|
|
|
| Weight |
|
|
|
|
.026 |
.026 |
3 |
.026 |
3 |
.026 |
.026 |
| Contact Material |
|
|
|
|
PdRu+Au |
PdRu+Au |
Nickel |
AgNi+Au |
Nickel |
PdRu+Au |
AgNi+Au |
| Coil Resistance |
|
|
|
|
178 |
145 |
1028 |
579 |
64 |
145 |
1029 |
| Insulation Initial Dielectric Between Open Contacts |
|
|
|
|
750 |
1000 |
600 |
750 |
600 |
1000 |
750 |
| Insertion Loss (HF Parameter) |
|
|
|
|
-.03dB @ 100MHz |
-.03dB @ 100MHz |
-.3dB @ 3GHz |
-.03dB @ 100MHz |
-.15dB @ 3GHz |
-.03dB @ 100MHz |
-.03dB @ 100MHz |
| Terminal Type |
|
|
|
|
PCB-THT |
PCB-SMT |
PCB-SMT |
PCB-SMT |
PCB-SMT |
PCB-SMT |
PCB-THT |
| Width |
|
|
|
|
.224 |
6 |
.295 |
6 |
.295 |
6 |
6 |
| Width Class (Mechanical) |
|
|
|
|
0 – 6 mm |
0 – 6 mm |
6 – 8 mm |
0 – 6 mm |
6 – 8 mm |
0 – 6 mm |
0 – 6 mm |
| Contact Limiting Making Current |
|
|
|
|
2 |
2 |
2 |
5 |
2 |
4 |
5 |
| Contact Voltage Rating |
|
|
|
|
220 |
220 |
220 |
220 |
220 |
220 |
220 |
| Insulation Initial Dielectric Between Contacts and Coil |
|
|
|
|
1500 |
1800 |
1000 |
1500 |
1000 |
1800 |
1500 |
| Additional Features |
|
|
|
|
Narrow |
Gull Wing |
Gull Wing |
Gull Wing |
Gull Wing |
Gull Wing |
|
| Isolation (HF Parameter) |
|
|
|
|
-18.8dB @ 900MHz |
-18.8dB @ 900MHz |
-55dB @ 3GHz |
-18.8dB @ 900MHz |
-30dB @ 6GHz |
-18.8dB @ 900MHz |
-18.8dB @ 900MHz |
| Environmental Ambient Temperature (Max) |
|
|
|
|
185 |
185 |
85 |
185 |
85 |
185 |
185 |
| Environmental Category of Protection |
|
|
|
|
RTV |
RTV |
RTIII |
RTV |
RTIII |
RTV |
RTV |
| Contact Number of Poles |
|
|
|
|
2 |
2 |
1 |
2 |
1 |
1 |
2 |
| Height |
|
|
|
|
5.8 |
5.65 |
10.5 |
5.65 |
10.5 |
5.65 |
5.65 |
| Coil Power Rating (DC) |
|
|
|
|
140 |
140 |
140 |
140 |
140 |
140 |
140 |
| Insulation Initial Resistance |
|
|
|
|
1000000 |
1000000 |
1000000 |
1000000 |
1000000 |
1000000 |
1000000 |
| Coil Voltage Rating |
|
|
|
|
5 |
5 |
12 |
9 |
3 |
5 |
12 |
| Coil Power Rating Class |
|
|
|
|
50 – 300 mW |
50 – 300 mW |
50 – 300 mW |
50 – 300 mW |
50 – 300 mW |
50 – 300 mW |
50 – 300 mW |
| Contact Limiting Continuous Current |
|
|
|
|
2 |
2 |
2 |
5 |
2 |
3 |
5 |
| Contact Limiting Short-Time Current |
|
|
|
|
2 |
2 |
2 |
5 |
2 |
4 |
5 |
| Insulation Initial Dielectric Between Adjacent Contacts |
|
|
|
|
750 |
1000 |
|
750 |
|
|
750 |
| Contact Switching Voltage (Max) |
|
|
|
|
220 |
220 |
220 |
220 |
220 |
220 |
220 |
| Insulation Initial Dielectric Between Coil/Contact Class |
|
|
|
|
1500 V – 2500 VA |
1500 V – 2500 VA |
500 – 1000 V |
1000 V – 1500 VA |
500 – 1000 V |
1500 V – 2500 VA |
1000 V – 1500 VA |
| Insulation Special Features |
|
|
|
|
2000V Initial Surge Withstand Voltage Between Contacts & Coil |
2500V Initial Surge Withstand Voltage between Contacts & Coil |
1500V Initial Surge Withstand Voltage between Contacts & Coil |
2000V Initial Surge Withstand Voltage Between Contacts & Coil |
1500V Initial Surge Withstand Voltage between Contacts & Coil |
2500V Initial Surge Withstand Voltage between Contacts & Coil |
2000V Initial Surge Withstand Voltage Between Contacts & Coil |
| Contact Special Features |
|
|
|
|
Bifurcated/Twin Contacts |
Bifurcated/Twin Contacts |
|
Bifurcated/Twin Contacts |
|
Bifurcated/Twin Contacts |
Bifurcated/Twin Contacts |
| Length |
|
|
|
|
10 |
10 |
14.9 |
|
14.9 |
10 |
10 |
| Length Class (Mechanical) |
|
|
|
|
0 – 10 mm |
0 – 10 mm |
14 – 16 mm |
0 – 10 mm |
14 – 16 mm |
0 – 10 mm |
0 – 10 mm |
| Contact Current Class |
|
|
|
|
0 – 2 A |
0 – 2 A |
0 – 2 A |
0 – 5 A |
0 – 2 A |
0 – 4 A |
0 – 5 A |
| Voltage Standing Wave Ration (HF Parameter) |
|
|
|
|
1.49 @ 900Mhz |
1.49 @ 900Mhz |
1.07 @ 100MHz |
1.49 @ 900Mhz |
1.07 @ 100MHz |
1.49 @ 900Mhz |
1.49 @ 900Mhz |
| Contact Limiting Breaking Current |
|
|
|
|
2 |
2 |
2 |
5 |
2 |
4 |
5 |
| Height Class (Mechanical) |
|
|
|
|
0 – 6 mm |
0 – 6 mm |
10 – 11 mm |
0 – 6 mm |
10 – 11 mm |
0 – 6 mm |
0 – 6 mm |
| Coil Type |
|
|
|
|
Monostable |
Monostable |
Monostable |
Monostable |
Monostable |
Monostable |
Monostable |
| Coil Magnetic System |
|
|
|
|
Monostable, DC, Polarized |
Monostable, DC, Polarized |
Monostable, DC |
Monostable, DC, Polarized |
Monostable, DC |
Monostable, DC, Polarized |
Monostable, DC, Polarized |
| Performance Type |
|
|
|
|
High Contact Stability |
Standard |
Standard |
High Current |
Standard |
Standard |
High Current |
| Contact Plating Material |
|
|
|
|
Gold |
Gold |
Gold |
Gold |
Gold |
Gold |
Gold |
| Contact Switching Load (Min) |
|
|
|
|
.1mA @ .0001V |
.1mA @ .0001V |
|
.1mA @ .0001V |
|
.1mA @ .0001V |
.1mA @ .0001V |
| Packaging Method |
|
|
|
|
Tube |
Reel |
Box & Carton |
Reel |
Box & Carton |
Reel |
Tube |
| Environmental Ambient Temperature Class |
|
|
|
|
70 – 85°C |
70 – 85°C |
70 – 85°C |
70 – 85°C |
70 – 85°C |
70 – 85°C |
70 – 85°C |