Phoenix Contact Ltd
3240531
|
Phoenix Contact Ltd
3240532
|
Hirose Electric Europe B.V.
PS4A-3.175T
|
TE Connectivity
D-200-83
|
TE Connectivity
696423-5
|
TE Connectivity
696424-5
|
TE Connectivity
6-160448-2
|
TE Connectivity
170341-1
|
TE Connectivity
170342-1
|
TE Connectivity
5-160526-7
|
| Price |
|
|
|
|
|
|
|
|
|
|
|
| RoHS |
|
Compliant |
Compliant |
Compliant |
|
|
|
|
|
|
|
| Lead Status |
|
Yes |
No |
|
|
|
|
|
|
|
|
| Splice Configuration |
|
|
|
|
Single to Single |
|
|
|
|
|
|
| Terminal & Splice Style |
|
|
|
|
Splice |
Ring Tongue |
Ring Tongue |
Receptacle |
Tab |
Receptacle |
Receptacle |
| Product Type |
|
|
|
|
Splice |
|
|
|
|
|
|
| Serrated |
|
|
|
|
No |
|
|
|
|
|
|
| Support Style |
|
|
|
|
Non-Insulation Support |
Insulation Support |
Insulation Support |
|
|
|
|
| Weight per Piece |
|
|
|
|
1.07 |
1.089 |
2.41 |
|
|
|
|
| Government Qualified |
|
|
|
|
Yes |
No |
No |
|
|
|
|
| Plating Material |
|
|
|
|
Nickel |
Tin |
Tin |
Tin |
Unplated |
Unplated |
Tin |
| Insulation Material |
|
|
|
|
Heat Shrink Radiation-Crosslinked Modified Fluoropolymer |
PVF2 |
PVF2 |
|
|
|
|
| Wire Size |
|
|
|
|
20 – 16 |
2800 – 4234 |
12 – 10 |
1.03 – 2.62 |
2.1 – 3.31 |
.51 – 2.08 |
20 – 15 |
| Sealable |
|
|
|
|
Yes |
No |
No |
No |
No |
No |
No |
| Number of Serrations |
|
|
|
|
0 |
|
|
|
|
|
|
| Barrel Type |
|
|
|
|
Closed Barrel |
Closed Barrel |
Closed Barrel |
Open |
Open |
Open |
Open |
| Insulated |
|
|
|
|
Yes |
Yes |
Yes |
No |
No |
No |
No |
| Operating Temperature Range |
|
|
|
|
-55 – 200 |
302 |
302 |
|
-22 – 221 |
-22 – 221 |
|
| Overall Length |
|
|
|
|
1.15 |
.85 |
1.088 |
19.2 |
26.4 |
.77 |
19.2 |
| Barrel Inside Diameter |
|
|
|
|
.067 |
|
|
|
|
|
|
| Packaging Quantity |
|
|
|
|
100 |
1000 |
500 |
5000 |
4000 |
6000 |
5000 |
| Wire/Cable Type |
|
|
|
|
Insulated Wire |
Regular Wire |
Regular Wire |
Regular Wire |
|
Discrete Wire |
Regular Wire |
| Termination Method |
|
|
|
|
Crimp |
|
|
|
|
|
|
| Heavy Duty |
|
|
|
|
No |
No |
No |
|
|
|
|
| Comment |
|
|
|
|
Parts will meet all performance requirements of SAE AS-81824 when properly installed. |
|
|
Chamfered |
|
|
Chamfered |
| Barrel Color |
|
|
|
|
Clear |
|
|
|
|
|
|
| Insulation Sleeve Material |
|
|
|
|
Fluoropolymer |
Copper |
Copper |
|
|
|
|
| Splice Material |
|
|
|
|
Nickel-Plated |
|
|
|
|
|
|
| Splice Features |
|
|
|
|
Splice Kit |
|
|
|
|
|
|
| Packaging Method |
|
|
|
|
Bag/Box |
Loose Piece |
Loose Piece |
Reel |
Reel |
Reel |
Reel |
| Accessory Type |
|
|
|
|
Splice |
|
|
|
|
|
|
| Splice Type |
|
|
|
|
In-Line Splice |
|
|
|
|
|
|
| Insulation Type |
|
|
|
|
|
Pre-Insulated |
Pre-Insulated |
|
|
|
|
| Wire Insulation Diameter (Max) |
|
|
|
|
|
3.81 |
.23 |
|
|
.134 |
|
| Tongue Thickness |
|
|
|
|
|
.79 |
.039 |
|
|
|
|
| Stud Size |
|
|
|
|
|
#8 |
#8 |
|
|
|
|
| Stripe Color |
|
|
|
|
|
Blue |
Yellow |
|
|
|
|
| Terminal Orientation |
|
|
|
|
|
Straight |
Straight |
Straight |
Straight |
Straight |
Straight |
| Wire Insulation Diameter |
|
|
|
|
|
.105 – .15 |
3.81 – 5.84 |
|
|
|
|
| Wire Insulation Diameter (Min) |
|
|
|
|
|
.105 |
|
|
|
|
|
| Barrel Style |
|
|
|
|
|
Long |
Long |
|
|
|
|
| Terminal Type |
|
|
|
|
|
Ring Tongue |
Ring Tongue |
Receptacle |
Tab |
Receptacle |
Receptacle |
| Inspection Slot |
|
|
|
|
|
No |
No |
|
|
|
|
| Insulation Support Sleeve Material |
|
|
|
|
|
Copper |
|
|
|
|
|
| Number of Holes |
|
|
|
|
|
1 |
1 |
|
|
|
|
| Wire Insulation Support |
|
|
|
|
|
With |
With |
With |
Without |
With |
With |
| Barrel Inside Diameter (Min) |
|
|
|
|
|
.153 |
|
|
|
|
|
| Military Part Class |
|
|
|
|
|
Class II |
Class II |
|
|
|
|
| Material Thickness |
|
|
|
|
|
.79 |
.039 |
|
|
|
|
| Terminal Angle |
|
|
|
|
|
Straight |
Straight |
|
|
|
|
| Stud Diameter |
|
|
|
|
|
.171 |
.171 |
|
|
|
|
| Terminal Features |
|
|
|
|
|
Sheared |
Sheared |
|
|
|
|
| Discrete Wire Type |
|
|
|
|
|
Stranded |
Stranded |
|
|
Stranded |
|
| Shape Code |
|
|
|
|
|
RING-042 |
RING-042 |
|
|
|
|
| FASTON |
|
|
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
| Disconnect Type |
|
|
|
|
|
|
|
Quick Disconnect |
Quick Disconnect |
Quick Connect |
Quick Disconnect |
| Wire Stop |
|
|
|
|
|
|
|
No |
No |
No |
No |
| Terminates To |
|
|
|
|
|
|
|
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
| Mating Retention Type |
|
|
|
|
|
|
|
Locking Lance |
|
|
Locking Lance |
| Receptacle Stock Thickness |
|
|
|
|
|
|
|
.013 |
.015 |
.012 |
.013 |
| Locking Lance Height |
|
|
|
|
|
|
|
.32 |
|
|
.32 |
| Fully Insulated |
|
|
|
|
|
|
|
No |
No |
No |
No |
| Mating Tab Thickness |
|
|
|
|
|
|
|
.81 |
.031 |
.61 |
.81 |
| Mating Tab Width |
|
|
|
|
|
|
|
6.35 |
.236 |
6.35 |
6.35 |
| Insertion Force |
|
|
|
|
|
|
|
Normal |
|
Normal |
Normal |
| Contact Base Material |
|
|
|
|
|
|
|
Phosphor Bronze |
Brass |
Brass |
Brass |
| Crimp Type |
|
|
|
|
|
|
|
F-Crimp |
F-Crimp |
F-Crimp |
F-Crimp |
| UL Flammability Rating |
|
|
|
|
|
|
|
UL 94V-2 |
|
|
|
| Accepts Wire Insulation Diameter Range |
|
|
|
|
|
|
|
.135 – .2 |
.114 – .15 |
2.21 – 3.4 |
.091 – .13 |
| Receptacle Terminal Stock Thickness |
|
|
|
|
|
|
|
.32 |
.4 |
.3 |
.32 |
| Voltage (Max) |
|
|
|
|
|
|
|
250 |
|
|
|
| Connection Capacity |
|
|
|
|
|
|
|
Single |
Single |
Single |
Single |
| Extraction Force |
|
|
|
|
|
|
|
|
|
.5 – 4 |
|
| Plating Thickness |
|
|
|
|
|
|
|
|
|
|
40 |