3D63UL
Altech
Altech 63A 3 Pole Thermal Magnetic Circuit Breaker, 240V ac UL. Terminal Contact Type: Box Clamp, Ring Tongue Terminal. Break Time: Time Delay. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 105.3 x 52.5 x 74.4mm. Overall Depth: 74.4mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type D. Mounting Style: DIN Rail Mount. Application: Heaters and Reactive Loads, High Inrush Motors, Power Supplies, Transformers. MPN: 3D63UL
Distributor | SKU | Stock | MOQ | 1 | 10 | 50 | 100 | 1,000 | 10,000 |
---|---|---|---|---|---|---|---|---|---|
DigiKey | 3D63UL | 0 | 1 | $107.07 | $107.07 | $107.07 | $107.07 | $107.07 | $107.07 |
Ameya360 | 3D63UL | 0 | $68.25 | $68.25 | $68.25 | $68.25 | $68.25 | $68.25 | |
Mouser Electronics | 3D63UL | 0 | 4 | $93.52 | $88.66 | $86.87 | $86.30 | $86.30 | |
Newark | 3D63UL | 0 | 1 | $115.17 | $106.99 | $96.46 | $92.96 | $92.96 | $92.96 |
RS Components | 3D63UL | 0 | $82.10 |
3E20UM
Altech
Altech 20A 3 Pole Thermal Magnetic Circuit Breaker, 480Y/277V V-EA. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 52.5 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type E. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Application: AC Discharge Lamps (Ballast), AC General Use, AC Incandescent Lamps (Tungsten), AC Motor Starting, AC Resistance, Across the Line, High Efficiency Motors, UL508 Application, Which have Exceedingly High Inrush Current. Special Features: IP20 Terminal Protection. MPN: 3E20UM
3E40UM
Altech
Altech 40A 3 Pole Thermal Magnetic Circuit Breaker, 480Y/277V V-EA. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 52.5 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type E. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Application: AC Discharge Lamps (Ballast), AC General Use, AC Incandescent Lamps (Tungsten), AC Motor Starting, AC Resistance, Across the Line, High Efficiency Motors, UL508 Application, Which have Exceedingly High Inrush Current. Mounting Style: DIN Rail Mount. Circuit Breaker Type: MCCB. MPN: 3E40UM
3G08UM
Altech
Altech 800mA 3 Pole Thermal Magnetic Circuit Breaker, 480Y/277V V-EA. Special Features: IP20 Terminal Protection. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 52.5 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type G. Break Time: Time Delay. Terminal Contact Type: Box Clamp, Ring Tongue Terminal. Overall Length: 93.3mm. MPN: 3G08UM
3G16UM
Altech
Altech 16A 3 Pole Thermal Magnetic Circuit Breaker, 480Y/277V V-EA. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 52.5 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type G. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Special Features: IP20 Terminal Protection. Mounting Style: DIN Rail Mount. MPN: 3G16UM
2G05UM
Altech
Altech 500mA 2 Pole Thermal Magnetic Circuit Breaker, 80 V dc, 480Y/277 V V-EA. Rated AC Voltage: 480Y/277V. Rated DC Voltage: 80V. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 35 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type G. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Special Features: IP20 Terminal Protection. Mounting Style: DIN Rail Mount. MPN: 2G05UM
2G40UM
Altech
Altech 40A 2 Pole Thermal Magnetic Circuit Breaker V-EA. Rated AC Voltage: 480Y/277V. Rated DC Voltage: 60V. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 35 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type G. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Special Features: IP20 Terminal Protection. Mounting Style: DIN Rail Mount. MPN: 2G40UM
2C10UM
Altech
Altech 10A 2 Pole Thermal Magnetic Circuit Breaker V-EA. Rated AC Voltage: 480Y/277V. Rated DC Voltage: 80V. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 35 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Tripping Characteristics: Type C. Breaking Capacity at Maximum Voltage Rating: 10 kA. Overall Length: 93.3mm. Circuit Breaker Type: MCCB. Mounting Style: DIN Rail Mount. Special Features: IP20 Terminal Protection. MPN: 2C10UM
Distributor | SKU | Stock | MOQ | 1 | 10 | 50 | 100 | 1,000 | 10,000 |
---|---|---|---|---|---|---|---|---|---|
DigiKey | 2C10UM | 13 | 1 | $47.60 | $47.60 | $47.60 | $47.60 | $47.60 | $47.60 |
element14 APAC | 2C10UM | 6 | 1 | $66.17 | $62.07 | $62.07 | $62.07 | $62.07 | $62.07 |
Farnell | 2C10UM | 6 | 1 | $39.51 | $35.56 | $32.23 | $32.23 | $32.23 | $32.23 |
Mouser Electronics | 2C10UM | 3 | 1 | $43.38 | $37.24 | $33.84 | $31.24 | $31.24 | $31.24 |
Newark | 2C10UM | 6 | 1 | $30.58 | $30.58 | $30.58 | $30.58 | $30.58 | $30.58 |
RS Components | 2C10UM | 0 | $35.20 |
2C30UM
Altech
Altech 30A 2 Pole Thermal Magnetic Circuit Breaker V-EA. Rated DC Voltage: 60V. Circuit Breaker Type: MCCB. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 35 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. Overall Length: 93.3mm. Application: AC Discharge Lamps (Ballast), AC General Use, AC Incandescent Lamps (Tungsten), AC Motor Starting, AC Resistance, Across the Line, Appliances, Business Equipment, Control Circuit Applications, Lighting, Low Inrush Motors, UL508 Application, Wiring Protection. Mounting Style: DIN Rail Mount. Tripping Characteristics: Type C. Breaking Capacity at Maximum Voltage Rating: 10 kA. Rated AC Voltage: 480Y/277V. MPN: 2C30UM
3E13UM
Altech
Altech 13A 3 Pole Thermal Magnetic Circuit Breaker, 480Y/277V V-EA. Mounting Style: DIN Rail Mount. Terminal Contact Type: Box Clamp, Ring Tongue Terminal. Break Time: Time Delay. Special Features: IP20 Terminal Protection. Overall Length: 93.3mm. Application: AC Discharge Lamps (Ballast), AC General Use, AC Incandescent Lamps (Tungsten), AC Motor Starting, AC Resistance, Across the Line, High Efficiency Motors, UL508 Application, Which have Exceedingly High Inrush Current. Reset Actuator Type: Handle. Overall Dimensions: 93.3 x 52.5 x 74.7mm. Overall Depth: 74.7mm. Tripping Mechanism: Thermal-Magnetic. MPN: 3E13UM