TE Connectivity
747844-6
|
TE Connectivity
216446-1
|
TE Connectivity
770904-1
|
TE Connectivity
794407-1
|
TE Connectivity
770902-4
|
TE Connectivity
770902-1
|
TE Connectivity
770904-3
|
TE Connectivity
770579-1
|
TE Connectivity
794781-1
|
TE Connectivity
770587-1
|
Price |
|
|
|
|
|
|
|
|
|
|
|
RoHS |
|
|
Compliant |
|
|
|
|
|
|
|
|
Lead Status |
|
|
No |
|
|
|
|
|
|
|
|
Contact Current Rating (Max) |
|
|
|
11.2 |
11.2 |
11.2 |
11.2 |
11.2 |
|
|
|
Contact Angle |
|
|
|
Straight |
Straight |
Straight |
Straight |
Straight |
|
|
|
Accepts Wire Insulation Diameter Range |
|
|
|
.059 – .094 |
.079 – .126 |
1.19 – 1.75 |
1.19 – 1.75 |
.059 – .094 |
|
|
|
Agency/Standard |
|
|
|
UL |
UL |
UL |
UL |
UL |
CSA |
|
CSA |
Glow Wire Rating |
|
|
|
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
Standard Part - Not Glow Wire |
CSA Rating |
|
|
|
Certified |
Certified |
Certified |
Certified |
Certified |
Certified |
|
Certified |
Termination Type |
|
|
|
Crimp |
Crimp |
Crimp |
Crimp |
Crimp |
|
|
|
Contact Mating Area Plating Material |
|
|
|
Pre-Tin |
Pre-Tin |
Pre-Tin |
Pre-Tin |
Gold |
|
|
|
Contact Type |
|
|
|
Socket |
Socket |
Socket |
Socket |
Socket |
Socket |
Socket |
Socket |
Wire/Cable Type |
|
|
|
Discrete Wire |
Discrete Wire |
Discrete Wire |
Discrete Wire |
Discrete Wire |
|
|
|
Connector & Contact Terminates To |
|
|
|
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire & Cable |
Wire/Cable Size |
|
|
|
22 – 18 |
20 – 16 |
.12 – .4 |
.12 – .4 |
22 – 18 |
|
|
|
VDE Tested |
|
|
|
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Wire Insulation Support |
|
|
|
Without |
Without |
Without |
Without |
Without |
|
|
|
Product Type |
|
|
|
Contact |
Contact |
Contact |
Contact |
Contact |
Housing |
Housing |
Housing |
Wire Contact Termination Area Plating Material |
|
|
|
Pre-Tin |
Pre-Tin |
Pre-Tin |
Pre-Tin |
Tin-Lead |
|
|
|
UL Rating |
|
|
|
Recognized |
Recognized |
Recognized |
Recognized |
Recognized |
Recognized |
|
Recognized |
Contact Retention in Housing |
|
|
|
With |
With |
With |
With |
With |
|
|
|
Circuit Application |
|
|
|
Power |
Power |
Power |
Power |
Power |
Power & Signal |
Power & Signal |
Power & Signal |
Packaging Quantity |
|
|
|
4500 |
4500 |
7000 |
7000 |
4500 |
1 |
1200 |
1 |
Operating Voltage |
|
|
|
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
CSA File Number |
|
|
|
LR 7189 |
LR 7189 |
LR 7189 |
LR 7189 |
LR 7189 |
LR7189 |
|
LR7189 |
For Multiple Crimp |
|
|
|
No |
No |
No |
No |
No |
|
|
|
Contact Base Material |
|
|
|
Brass |
Brass |
Phosphor Bronze |
Brass |
Brass |
|
|
|
Contact Termination Area Plating Material |
|
|
|
Pre-Tin |
Pre-Tin |
Pre-Tin |
Pre-Tin |
Tin-Lead |
|
|
|
Mating Pin Diameter |
|
|
|
.028 |
1 |
1 |
1 |
.028 |
|
|
|
Comment |
|
|
|
HDM Applicator part number ending in -1 is used on AMPOMATOR CLS Machine with T or G Terminators, -2 is used on AMP-O-LECTRIC Model K Machine, -3 is used on AMP-O-LECTRIC Model G Machine. |
|
HDM Applicator part number ending in -3 is used on AMPOMATOR CLS Machine with T or G Terminators, -4 is used on AMP-O-LECTRIC Model K Machine, -5 is used on AMP-O-LECTRIC Model G Machines. |
HDM Applicator part number ending in -3 is used on AMPOMATOR CLS Machine with T or G Terminators, -4 is used on AMP-O-LECTRIC Model K Machine, -5 is used on AMP-O-LECTRIC Model G Machines. |
HDM Applicator part number ending in -1 is used on AMPOMATOR CLS Machine with T or G Terminators, -2 is used on AMP-O-LECTRIC Model K Machine, -3 is used on AMP-O-LECTRIC Model G Machine. |
|
|
|
For Use With |
|
|
|
Plug Housing |
Plug Housing |
Plug Housing |
Plug Housing |
Plug Housing |
Mini-Universal MATE-N-LOK Cap Housing |
Mini-Universal MATE-N-LOK Sealed Cap Housing |
Mini-Universal MATE-N-LOK Cap Housing |
Operating Temperature Range |
|
|
|
-67 – 221 |
-67 – 221 |
-67 – 221 |
-67 – 221 |
-67 – 221 |
-20 – 105 |
-20 – 105 |
-20 – 105 |
UL File Number |
|
|
|
E28476 |
E28476 |
E28476 |
E28476 |
E28476 |
|
|
|
Connector Mounting Type |
|
|
|
Cable Mount |
Cable Mount |
Cable Mount |
Cable Mount |
Cable Mount |
Cable Mount |
Cable Mount |
Cable Mount |
Wire Type |
|
|
|
Stranded |
Stranded |
Stranded |
Stranded |
Stranded |
|
|
|
Packaging Method |
|
|
|
Reel |
Reel |
Reel |
Reel |
Reel |
Package |
Package |
Package |
Connector System |
|
|
|
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
Wire-to-Wire |
UL Flammability Rating |
|
|
|
|
|
UL 94V-0 |
UL 94V-0 |
|
UL 94V-2 |
UL 94V-0 |
UL 94V-0 |
Underplate Material Thickness |
|
|
|
|
|
|
|
1.27 |
|
|
|
Contact Termination Area Plating Thickness |
|
|
|
|
|
|
|
2.54 |
|
|
|
Contact Mating Area Plating Thickness |
|
|
|
|
|
|
|
.76 |
|
|
|
Crimp Area Plating Thickness |
|
|
|
|
|
|
|
2.54 |
|
|
|
Crimp Area Plating Finish |
|
|
|
|
|
|
|
Bright |
|
|
|
Contact Underplating Material |
|
|
|
|
|
|
|
Nickel |
|
|
|
Row-to-Row Spacing |
|
|
|
|
|
|
|
|
.162 |
.162 |
.163 |
Housing Material |
|
|
|
|
|
|
|
|
Nylon |
Nylon |
Nylon |
Agency/Standard Number |
|
|
|
|
|
|
|
|
E28476 |
|
E28476 |
Assembly Integration Feature |
|
|
|
|
|
|
|
|
Without |
Without |
Without |
Number of Rows |
|
|
|
|
|
|
|
|
2 |
2 |
2 |
Contact Retention |
|
|
|
|
|
|
|
|
Without |
Without |
Without |
Multiple Contact Types |
|
|
|
|
|
|
|
|
Without |
Without |
Without |
Centerline (Pitch) |
|
|
|
|
|
|
|
|
.162 |
.162 |
4.14 |
Housing Color |
|
|
|
|
|
|
|
|
White |
White |
White |
Housing Type |
|
|
|
|
|
|
|
|
Plug |
Plug |
Plug |
Termination Method to Wire & Cable |
|
|
|
|
|
|
|
|
Crimp |
Crimp |
Crimp |
Number of Positions |
|
|
|
|
|
|
|
|
8 |
10 |
24 |
Panel Mount Feature |
|
|
|
|
|
|
|
|
Without |
Without |
Without |
Sealable |
|
|
|
|
|
|
|
|
No |
No |
No |
Height |
|
|
|
|
|
|
|
|
|
15.21 |
|
Width |
|
|
|
|
|
|
|
|
|
20.68 |
|
Length |
|
|
|
|
|
|
|
|
|
24.97 |
|